Lux TX9100U-006

Lux TX9100U-006 manual

(1)
  • R
    W
    Y
    G
    LUX
    ®
    TX9100U UNIVERSAL PROGRAMMABLE THERMOSTAT
    QUICK START INSTALLATION GUIDE
    53000
    1
    2
    3
    4
    5
    6
    OFF
    Turn OFF the power to both
    your heating and cooling units
    at the circuit breaker.
    BEFORE removing thermostat, label your
    existing wire connections with the labels
    provided. Cover any “unused” wires with
    electrical tape.
    Thank you for choosing LUX Products, and
    we hope that you will enjoy using your new
    thermostat along with its many energy
    saving features.
    This sheet is just a quick start guide, and there are many more instructions and topics covered in the full version of the manual for
    this product. The complete version PDF can be obtained at “http://www.luxproducts.com”. Click on SUPPORT, then
    INSTRUCTION MANUALS.
    Restore the power to your heating and cooling units.
    Install new Alkaline
    batteries into the thermostat. NOTE:
    Please use Duracell or Energizer Alkaline batteries ONLY for
    all LUX
    ®
    thermostats requiring batteries. BE SURE TO
    CHANGE THE BATTERIES AT LEAST ONCE A YEAR, to ensure
    consistent and reliable operation of your heating/cooling
    system.
    Set the system switch to the
    desired temperature mode.
    Adjust the SET Temperature to the
    desired comfort setting.
    (NOTE: this set point will only be
    temporary until the program
    periods are saved in memory.)
    LABEL WIRES
    INSTALL ALKALINE BATTERIES
    INSTALL NEW THERMOSTAT BASE
    TEST HEAT AND COOL OPERATION
    SET THE CLOCK...
    SET THE TEMPERATURE PROGRAMS
    DOWNLOAD THE FULL INSTRUCTION MANUAL
    If you are having difficulties with the installation or the operation of your thermostat, please review the online troubleshooting
    guides for your model. These troubleshooting guides cover the most common symptoms that you may observe. The
    Troubleshooting Guides are located at “http://www.luxproducts.com”. Click on SUPPORT, then TROUBLESHOOTING GUIDES.
    ONLINE THERMOSTAT TROUBLESHOOTING GUIDES
    If you require need assistance with your product, please contact our Technical Assistance department between 8:00AM and
    4:30PM Eastern Time from Monday through Friday, at 856-234-8803. Our website also permits you to email your technical
    questions to our support staff at your convenience by visiting “http://www.luxproducts.com”, and clicking on the CONTACT US tab
    at the top of the page.
    © 2012 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
    CONTACT OUR TECHNICAL SUPPORT DEPARTMENT
    SHUT OFF POWER
    HEAT
    OFF
    COOL
    72F
    70F
    68F
    Remove your old thermostat. Install the new thermostat
    base (using the same mounting holes if possible). Connect
    the wires matching the exact terminal letters from your wires,
    to the terminal letters on the new thermostat.
    NOTE:
    If you have both a “B” and an “O” wire, see the notes
    on the back page of this instruction sheet.
    4
    C
    H
    O
    RH
    5
    C1
    H1
    OT
    T
    6
    DH
    H2
    OT
    TC
    A
    E
    MDO
    R
    V
    AU
    F
    L
    R
    V
    W3 EGYROW2BL
    R
    G
    O
Lux TX9100U-006

¿Necesita ayuda?

Número de preguntas: 0

¿Tiene alguna pregunta sobre Lux TX9100U-006 o necesita ayuda? Haga su pregunta aquí. Proporcione una descripción clara y completa del problema y su pregunta. Cuantos más detalles proporcione para su problema y pregunta, más fácil será para otros propietarios de Lux TX9100U-006 responder adecuadamente a su pregunta.

Vea el manual de Lux TX9100U-006 aquí, de forma gratuita. Este manual pertenece a la categoría Termostatos y ha sido calificado por 1 personas con un promedio de 7.5. Este manual está disponible en los siguientes idiomas: Inglés. ¿Tiene alguna pregunta sobre Lux TX9100U-006 o necesita ayuda? Haz tu pregunta aquí

Especificaciones de Lux TX9100U-006

General
Marca Lux
Modelo TX9100U-006
Producto Termostato
Idioma Inglés
Tipo de archivo PDF