    Thank you for purchasing the OMRON M3 IT Automatic Blood Pressure Monitor.
    The OMRON M3 IT is a compact, fully automatic blood pressure monitor, operating
    on the oscillometric principle. It measures your blood pressure and pulse rate simply
    and quickly. For comfortable controlled inflation without the need of pressure
    pre-setting or re-inflation the device uses its advanced “IntelliSense” technology.
    Intended Use
    This device is a digital monitor intended for use in measuring blood pressure and
    pulse rate in adult patient population who can understand this instruction manual
    with the arm circumference range printed on the arm cuff. The device detects the
    appearance of irregular heartbeats during measurement and gives a warning signal
    with the measurement result.
    Please read this instruction manual thoroughly before using the device.
    Please keep for future reference. For specific information about your own blood
    pressure, CONSULT YOUR PHYSICIAN.
    Important Safety Information
    Warning: Indicates a potentially hazardous situation which, if not avoided,
    could result in death or serious injury.
    (General Usage)
    Consult your physician before using the device in pregnancy including
    pre-eclampsia, or if diagnosed with arrhythmia or arteriosclerosis.
    Do not use the device on the injured arm or the arm under medical treatment.
    Do not apply the arm cuff on the arm while being on an intravenous drip or blood
    transfusion.
    Consult your physician before using the device on the arm with an arterio-venous
    (A-V) shunt.
    Do not use the device with other medical electrical (ME) equipment
    simultaneously.
    Do not use the device in the area the HF surgical equipment, MRI, or CT scanner
    exists, or in the oxygen rich environment.
    The air tube or the AC adapter cable may cause accidental strangulation in
    infants.
    Contained small parts that may cause a choking hazard if swallowed by infants.
    (AC Adapter (optional) Usage)
    Do not use the AC adapter if the device or the power cord is damaged. Turn off
    the power and unplug the power cord immediately.
    Plug the AC adapter into the appropriate voltage outlet. Do not use in a
    multi-outlet plug.
    Never plug in or unplug the power cord from the electric outlet with wet hands.
    Caution: Indicates a potentially hazardous situation which, if not avoided,
    may result in minor or moderate injury to the user or patient or
    damage to the equipment or other property.
    (General Usage)
    Always consult your physician. Self-diagnosis of measurement results and
    self-treatment are dangerous.
    People with severe blood flow problems, or blood disorders, should consult a
    physician before using the device, as the arm cuff inflation can cause bruising.
    If there are any abnormalities during the measurement, remove the arm cuff.
    Do not use this device on infants or persons who cannot express their intentions.
    Do not inflate the arm cuff more than necessary.
    Do not use the device for any purpose other than measuring blood pressure.
    Use only the approved arm cuff for this device. Use of other arm cuffs may result
    in incorrect measurement results.
    Do not use a mobile phone or other devices that emit electromagnetic fields,
    near the device. This may result in incorrect operation of the device.
    Do not disassemble the monitor or arm cuff.
    Do not use in a location with moisture, or a location where water may splash on
    the device. This may damage the device.
    Do not use the device in a moving vehicle (car, airplane).
    Do not take measurements more than necessary. It may cause bruising due to
    blood flow interference.
    Consult your physician before using the device if you had a mastectomy.
    (AC Adapter (optional) Usage)
    Fully insert the power plug into the outlet.
    When disconnecting the power plug from the outlet, do not pull the power cord.
    Be sure to pull from the power plug safely.
    When handling the power cord, take care not to do the following:
    Wipe the dust off from the power plug.
    Unplug monitor when not in use.
    Disconnect the power plug before cleaning.
    Use only the original adapter designed for this device. Use of unsupported
    adapters may damage and/or may be hazardous to the device.
    (Battery Usage)
    Do not insert the batteries with their polarities incorrectly aligned.
    Use only 4 “AA” alkaline or manganese batteries with this device. Do not use
    other types of batteries. Do not use new and used batteries together.
    Remove the batteries if the device will not be used for three months or more.
    General Precautions
    Do not forcibly crease the arm cuff or the air tube excessively.
    Do not press the air tube while taking a measurement.
    To unplug the air plug, pull on the air plug at the connection with the monitor, not
    the tube itself.
    Do not drop the monitor or subject device to strong shocks or vibrations.
    Do not inflate the arm cuff when it is not wrapped around your arm.
    Do not use the device outside the specified environment. It may cause an
    inaccurate result.
    Read and follow the "Important information regarding Electro Magnetic
    Compatibility (EMC)" in the "6. Specifications".
    Read and follow the "Correct Disposal of This Product" in "6. Specifications" when
    disposing of the device and any used accessories or optional parts.
    1. Know Your Device
    Contents:
    Monitor, arm cuff, instruction manual, storage case, battery set,
    USB cable, blood pressure pass
    Monitor:
    Arm cuff:
    Display:
    Display symbols:
    Irregular Heartbeat Symbol ( )
    When the monitor detects an irregular
    rhythm two or more times during the
    measurement, the irregular heartbeat
    symbol ( ) will appear on the display
    with the measurement values.
    An irregular heartbeat rhythm is defined
    as a rhythm that is 25% less or 25%
    more than the average rhythm detected
    while the monitor is measuring the systolic and diastolic blood pressure.
    If the irregular heartbeat symbol ( ) displays with your measurement results,
    we recommend you consult your physician. Follow the directions of your
    physician.
    Movement Error Symbol ( )
    The movement error symbol is displayed if you move your body during the
    measurement. Please remove the arm cuff, and wait 2 - 3 minutes.
    Take another measurement, remain still during measurement.
    Average Value Symbol ( )
    The average value symbol is displayed when you press and hold the memory
    button for more than 3 seconds. The most recent average value appears on
    the display screen.
    Cuff Wrap Guide Lamp ( )
    If the cuff was wrapped too loosely, it may cause unreliable values. If the
    wrapping of cuff is too loose, the cuff wrap guide lamp does not light.
    Otherwise
    lights in green. This is the function which is used as an aid in
    determining if the cuff is wrapped snugly enough.
    Blood Pressure Colour Indicator
    If your systolic or diastolic pressure is above the
    standard range (135 mmHg for the systolic blood
    pressure and/or 85 mmHg for the diastolic blood
    pressure), the blood pressure colour indicator will light
    in orange when the measurement result is displayed.
    If they are within the standard range, no light will
    appear.
    The JNC7* Guideline recommends the following guideline.
    These are form statistical values for blood pressure.
    * JNC7: The Seventh Report, 2003 Dec, of the Joint National Committee on
    Prevention, Detection, Evaluation, and Treatment of Hi Blood
    Pressure.
    2. Preparation
    2.1 Battery Installation
    1. Remove the battery cover.
    2. Insert 4 “AA” batteries as
    indicated in the battery
    compartment.
    3. Replace the battery cover.
    Notes:
    • When the low battery symbol ( ) appears on the display, turn the monitor
    off, then replace all batteries at the same time. Long life alkaline batteries
    are recommended.
    • The measurement values continue to be stored in memory even after the
    batteries are replaced.
    • The supplied batteries may have a shorter life.
    Disposal of used batteries should be carried out in accordance with the
    national/local regulations for the disposal of batteries.
    2.2 Setting the Date and Time
    Set the monitor to the correct date and time before taking a measurement for
    the first time.
    1. Press the button.
    2. Push or to change the year
    Push button to confirm the year and then the month flashes. Repeat the
    same steps to change the month, day, hour, and minutes.
    3. Press the START/STOP button to turn the monitor off.
    Notes:
    • If the batteries have been replaced, the date and time setting will need to be
    reset.
    • If the date and time are not set, “-:--” appears during or after measurement.
    3. Using the Device
    3.1 Applying the Arm Cuff
    Remove tight-fitting clothing or tight rolled up sleeve from your left upper arm.
    Do not place the arm cuff over thick clothes.
    1. Insert the air plug into the air jack
    securely.
    2. Apply the arm cuff to your left
    upper arm.
    The bottom edge of the arm cuff
    should be 1 to 2 cm above the elbow.
    Air tube is on the inside of your arm
    and aligned with your middle finger.
    3. Secure closed with the
    fabric fastener.
    Notes:
    • When you take a measurement on the right
    arm, the air tube will be at the side of your
    elbow. Be careful not to rest your arm on the
    air tube.
    • The blood pressure can differ between the right arm and the left arm, and
    therefore also the measured blood pressure values can be different.
    OMRON recommends to always use the same arm for measurement. If the
    values between both arms differ substantially, please check with your
    physician which arm to use for your measurement.
    3.2 How to Sit Correctly
    To take a measurement, you need to be
    relaxed and comfortably seated, under
    comfortable room temperature. Avoid
    bathing, drinking alcohol or caffeine,
    smoking, exercising or eating 30 minutes
    before taking a measurement.
    • Sit on a chair with your feet flat on the floor.
    • Sit upright with your back straight.
    • Sit with your back and arm being supported.
    • The arm cuff should be placed on your arm at
    the same level as your heart.
    3.3 Taking a Measurement
    Notes:
    • To cancel a measurement, press the START/STOP button to release the air
    in the arm cuff.
    • Remain still while taking a measurement.
    The monitor is designed to take measurements and store the measurement
    values in the memory for 2 people using USER ID 1 and USER ID 2.
    1. Select your User ID (1 or 2).
    2. Press the START/ STOP button.
    The arm cuff will start to inflate automatically.
    3. Remove the arm cuff.
    4.
    Press the START/STOP button to turn the monitor off.
    The monitor automatically stores the measurement result in its memory.
    It will automatically turn off after 2 minutes.
    Note: Wait 2-3 minutes before taking another measurement. Waiting between
    measurements allows the arteries to return to the condition prior to
    taking a measurement.
    Using the Guest Mode
    The monitor stores measurement values for 2 users in the memory.
    The guest mode can be used to take a single measurement for another user.
    No measurement values are stored in the memory when the guest mode is
    selected.
    1. Press and hold the START/STOP
    button for more than 3 seconds.
    The USER ID symbol and the Date/Time
    display will disappear.
    2. Release the START/STOP button when the Date/Time display
    turns off.
    The arm cuff will start to inflate automatically.
    Always consult your physician. Self-diagnosis of measurement results and
    self-treatment are dangerous.
    3.4 Using the Memory Function
    The monitor automatically stores the results up to 60 sets for each user (1 and
    2). It can also calculate an average value based on the last 3 measurement
    values taken within 10 minutes.
    Notes:
    • If there are only 2 measurement values in the memory for that period, the
    average will be based on these 2 values.
    • If there is 1 measurement value in the memory for that period, this is
    displayed as the average.
    • If the memory is full, the monitor will delete the oldest value.
    • When viewing the measurement value taken without setting the date and
    time, “-:--” is displayed instead of the date and time.
    To View the Measurement Values Stored in Memory
    1. Select your User ID (1 or 2).
    2. Press the button.
    The Memory number appears for a second
    before the pulse rate is displayed.
    The newest set is numbered “1”.
    Note: The cuff wrap guide result appears on
    the display with the measurement
    values. The cuff wrap guide lamp will not
    light.
    : The arm cuff was wrapped snugly enough.
    : The arm cuff was loose or not wrapped correctly.
    3. Press the or button to view the values stored in memory.
    :
    To the older values
    : To the more recent values
    To View the Average Value
    1. Select your User ID (1 or 2).
    2. Press and hold the button for
    more than 3 seconds.
    Notes:
    • If the previous measurement was taken without setting the date and time,
    the average value is not calculated.
    • If there are no measurements results stored in the memory,
    the screen to the right is displayed.
    To Transfer the Measurement Values
    To begin using the Medical Link software for the first time, please visit
    www.omron-healthcare.com for the initial set-up instructions.
    1. Open the USB port cover.
    2. Connect the USB cable to a PC.
    3. Connect the USB cable to the monitor.
    To Delete All the Values Stored in Memory
    1. Select your User ID (1 or 2).
    2. Press the Memory button, while the memory symbol ( )
    appears.
    3. While holding the button
    down, press the
    START/STOP button for
    more than 3 seconds.
    Note: You cannot partially delete the values stored in the memory.
    All values for the user you select will be deleted.
    Do not damage. Do not break it.
    Do not tamper with it. Do not forcibly bend or pull.
    Do not twist. Do not bundle during use.
    Do not pinch. Do not place under heavy objects.
    Automatic Blood
    Pressure Monitor
    Model M3 IT
    Instruction Manual
    IM-HEM-7131U-E-EN-01-08/2013
    2298868-3A
    A. Display
    B. Memory button
    C. START/ STOP button
    D. Date/ Time setting button
    E. USER ID selection switch
    F. Cuff wrap guide lamp
    G. Up/ Down buttons
    H. Blood pressure colour indicator
    I. Battery compartment
    J. AC adapter jack
    (for optional AC adapter)
    K. USB port
    L. Air jack
    P. OK symbol
    Q. Transfer indicator
    R. USER ID symbol
    S. DATA/FULL symbol
    T. Systolic blood pressure
    U. Diastolic blood pressure
    V. Low battery symbol
    W. Cuff wrap guide
    X. Heartbeat symbol
    (Flashes during measurement.)
    Y. Memory symbol
    Z. Average value symbol
    AA. Date/Time display
    AB. Movement error symbol
    AC.Irregular heartbeat symbol
    AD.Blood pressure level indicator
    AE. Deflation symbol
    AF. Pulse display / Memory number
    General Guidelines for Blood Pressure
    Prehypertension at Office Hypertension at Home
    Systolic Blood Pressure 120 - 139 mmHg 135 mmHg
    Diastolic Blood Pressure 80 - 89 mmHg 85 mmHg
    I
    L K
    J
    D
    A
    B
    C
    G
    F
    E
    DD
    H
    M
    O
    N
    M. Arm cuff (Arm circumference 22 - 42 cm)
    N. Air plug
    O. Air tube
    S
    T
    U
    V
    Y
    R
    Q
    P
    Z
    AA
    W
    X
    AB
    AC
    AD
    AE
    AF
    Normal Heartbeat
    Irregular Heartbeat
    Long
    Short
    Blood pressure
    Blood pressure
    Pulse
    Pulse
    Minute
    Change Confirm
    Change Confirm
    Change Confirm
    Change Confirm
    Change Confirm
    Year
    Month
    Day
    Hour
    : Forward
    : Back
    1 - 2 cm
    Cuff Wrap Guide Lamp
    START INFLATE DEFLATE COMPLETE
    If your systolic pressure is more than 210 mmHg
    After the arm cuff starts to inflate, press and hold the START/ STOP
    button until the monitor inflates 30 to 40 mmHg higher than your
    expected systolic pressure.
    Notes:
    The monitor will not inflate above 299 mmHg.
    Do not apply more pressure than necessary.
    Alternating date/ time
    display
Omron M3 IT

¿Necesita ayuda?

Número de preguntas: 0

¿Tiene alguna pregunta sobre Omron M3 IT o necesita ayuda? Haga su pregunta aquí. Proporcione una descripción clara y completa del problema y su pregunta. Cuantos más detalles proporcione para su problema y pregunta, más fácil será para otros propietarios de Omron M3 IT responder adecuadamente a su pregunta.

Vea el manual de Omron M3 IT aquí, de forma gratuita. Este manual pertenece a la categoría Esfigmomanómetros y ha sido calificado por 1 personas con un promedio de 7.6. Este manual está disponible en los siguientes idiomas: Engels. ¿Tiene alguna pregunta sobre Omron M3 IT o necesita ayuda? Haz tu pregunta aquí

Especificaciones de Omron M3 IT

General
Marca Omron
Modelo M3 IT
Producto Esfigmomanómetro
EAN 4015672108370
Idioma Engels
Tipo de archivo PDF
Características
Tipo Automático
Colocación soportada Antebrazo
Número de usuarios 2 usuario(s)
Impresión de fecha Si
presión arterial media Si
De medición del pulso índice Si
presión arterial diastólica Si
Presión arterial sistólica Si
Tamaño de cadena 22 - 42 cm
Función de la memoria Si
Función de voz -
Ranuras de memoria 120
Control de energía
Numero de baterías soportadas 4
Tipo de batería AA
Exhibición
Tipo de visualizador LCD
Empaquetado
Número de productos incluidos 1 pieza(s)
Contenido del embalaje
Funda de transporte Si
Pilas incluidas Si

ManualPDF.es

¿Busca un manual? ManualPDF.es asegura que encontrará el manual que está buscando en un abrir y cerrar de ojos. Nuestra base de datos contiene más de 1 millón de manuales en PDF de más de 10.000 marcas. Cada día añadimos los últimos manuales para que siempre encuentres el producto que buscas. Es muy sencillo: simplemente escriba el nombre de la marca y el tipo de producto en la barra de búsqueda y podrá ver instantáneamente el manual de su elección en línea de forma gratuita.

ManualPDF.es

© Copyright 2021 ManualPDF.es. Todos los derechos reservados.

Utilizamos cookies para asegurar que damos la mejor experiencia al usuario en nuestro sitio web. Si continúa utilizando este sitio asumiremos que está de acuerdo.

Leer más