    Using micro current technology the Electrolysis Hair Remover
    destroys the hair root and papilla to prevent future hair growth.
    The micro current changes the pH in the hair follicle to alkaline
    which then starts to attack the hair root and papilla cells (it is
    these cells which are responsible for hair growth). This action
    continues for sometime after the treatment is complete and
    the hair has been removed.
    It is not always possible to kill all of the papilla cells in a single
    treatment and in these situations the hair may regrow. If it does
    regrow it is generally much finer and lighter than previously.
    Successive treatments will kill the papilla cells giving a
    permanent result. You may use your normal epilation
    methods in between treatments.
    The destruction of the hair root cells continues for some
    time after the treatment has finished. It makes no difference
    whether you remove the hair immediately or not.
    If there is a particularly stubborn hair, an additional treatment
    or longer treatment time may be required.
    As with all hair removal treatments it is recommended that
    the area you have treated is washed with cool water and a
    mild antiseptic cream applied.
    TIPS
     
    detect the conductive gel.
     
    battery power is low and it needs replacing.
     
    The use of a good quality, leak-proof alkaline battery
    is recommended.
     
    the battery or unplug from the mains.
     
    power adapter, which plugs into the adapter socket on
    the side. To order please call the Customer Careline.
     
     
     
    on the console unit and do not use them for any other
    purpose than intended.
     
    cloth, the console unit can also be wiped over.
    1. Console
     
    3. Treatment indicator
    (AMBER)
    4. Control dial
    5. Treatment complete
    
    6. Wand output socket
    7. Power adapter socket
    (optional extra available
    from the Customer Careline)
    8. Tweezer Socket
     
    10. Conductive gel
    
    YOUR ELECTROLYSIS
    HAIR REMOVER
    CONDUCTIVE GEL
    professional range
    BODY CARE
    BATTERY 9V PP3
    1
    9
    0
    !
    8
    5
    7
    
    Problem Fault/Cause remedy
    Amber treatment
    light does not
    
    and console
    bleeps.
    Good contact
    with the hair
    is not being
    maintained or
    your finger is not
    touching tweezer
    button.
    Check tweezers
    are connected
    Ensure you are
    using gel.
    Grasp hair at
    skin level.
    The amber light
    has gone out and
    the console is
    bleeping.
    The contact
    with the hair or
    tweezer button
    has been lost.
    If the contact is not
    re-established
    within three
    seconds the
    treatment timer will
    assume you have
    moved onto a new
    hair and restart
    the treatment from
    the beginning.
    Grasp hair
    at skin level.
    The console is
    bleeping and the
    power light is
    flashing.
    Console left on -
    and not used.
    Turn the
    console off.
    Console is
    bleeping
    constantly.
    Low Battery. Replace battery.
    The hair is
    difficult to
    remove.
    More than a
    single treatment
    is required to kill
    this hair.
    If there is a lot
    of resistance
    an additional
    treatment or longer
    treatment time of
    the same hair
    may be required
    Hair regrows.
    It is not always
    possible to kill
    all of the papilla
    cells in a single
    treatment.
    Repeat the
    treatment when the
    hair grows back.
    Use a longer
    treatment time.
    Redness of skin
    after treatment.
    This is quite
    normal, you may
    wish to apply an
    antiseptic cream,
    however the
    redness should
    fade within one
    or two hours.
    Treatment light
    on continuously.
    Contact is being
    maintained
    even when the
    tweezers are not
    in use.
    Clean tweezers
    with a damp
    cloth thoroughly,
    removing all traces
    of conductive gel.
    1-IN-CNHR2-UK / 1.1
    2
    6
    3
    4
    © The Dezac Group
    © The Dezac Group
    © The Dezac Group
Rio CNHR2

¿Necesita ayuda?

Número de preguntas: 0

¿Tiene alguna pregunta sobre Rio CNHR2 o necesita ayuda? Haga su pregunta aquí. Proporcione una descripción clara y completa del problema y su pregunta. Cuantos más detalles proporcione para su problema y pregunta, más fácil será para otros propietarios de Rio CNHR2 responder adecuadamente a su pregunta.

Vea el manual de Rio CNHR2 aquí, de forma gratuita. Este manual pertenece a la categoría Aparatos de Depilación Láser y ha sido calificado por 1 personas con un promedio de 8.2. Este manual está disponible en los siguientes idiomas: Inglés. ¿Tiene alguna pregunta sobre Rio CNHR2 o necesita ayuda? Haz tu pregunta aquí

Especificaciones de Rio CNHR2

General
Marca Rio
Modelo CNHR2
Producto Aparato de Depilación Láser
EAN 5019487083692
Idioma Inglés
Tipo de archivo PDF
Características
Número de pinzas -pinzas
Color del producto Blanco
Afeitadora
Recortadora
Lavable
Mojado y seco
Refrigeración
Cabezal flotante
Retroiluminación
Función de masaje
Control de energía
Recargable
Tecnología de batería Alcali✗
Tipo de batería -
Voltaje de la pila 9V
Numero de baterías soportadas 1
Otras características
Batería
Contenido del embalaje
Cabezal para cara incluido
Pilas incluidas
Peso y dimensiones
Ancho 150mm
Profundidad 150mm
Altura 75mm
Peso 300g
Empaquetado
Ancho del paquete 205mm
Profundidad del paquete 113mm
Altura del paquete 243mm
Peso del paquete 629g

ManualPDF.es

¿Busca un manual? ManualPDF.es asegura que encontrará el manual que está buscando en un abrir y cerrar de ojos. Nuestra base de datos contiene más de 1 millón de manuales en PDF de más de 10.000 marcas. Cada día añadimos los últimos manuales para que siempre encuentres el producto que buscas. Es muy sencillo: simplemente escriba el nombre de la marca y el tipo de producto en la barra de búsqueda y podrá ver instantáneamente el manual de su elección en línea de forma gratuita.

ManualPDF.es

© Copyright 2020 ManualPDF.es. Todos los derechos reservados.

Utilizamos cookies para asegurar que damos la mejor experiencia al usuario en nuestro sitio web. Si continúa utilizando este sitio asumiremos que está de acuerdo.

Leer más